Model fP 6400
General
Number of input channels 2
Number of output channels 2
Peak output voltage 149 V
8 ohms load 104 Vrms
Max output power (all channels driven)
8 ohms 1 1300 W
4 ohms 1 2300 W
2 ohms 1 3000 W
Max output power bridged
8 ohms 4600 W
4 ohms 6000 W
Performance
THD + N 20 Hz – 20 kHz for 1 W 0.1 %
THD + N at 1 kHz and 1 dB below clipping 0.04 %
DIM 30 at 3 dB below clipping 0.06 %
Hum and noise < -110 dB
Output impedance 60 mΩ
Slew rate 20 V/μsec
Common mode rejection 50 dB
Connectors and Buttons
Gain selectable [dB] 5) 2 20, 23, 26, 29, 32, 35, 38, 41
Gain controls 31 pos detent
Clip Red LED
Output headroom indicators 5 green LED’s
VHF Yellow LED
Over temperature Yellow LED
Back panel user interface
Inputs Neutrik Combo
Link connectors XLR male
Clip limiters On/Off, each ch.
MLS switch [dB] 0, -2, -4, -5
corresponding to [Vrms] 104, 84, 70, 62
when bridged [Vrms] 208, 168, 140, 124
Link switch Ch. A-B
Power
Operating voltage 130-265V/65-135V
Soft start / Inrush power Yes / max. 5 A
Full output power at 4 ohms, 230V/115V 180-265V/90-130V
Minimum start-up voltage, 230V/115V 175V/95V
230 V or 115 V versions Yes
Current draw at 4 ohms and 230V/115V
Idle, no load at output 1.0/2.0 Arms
1/8 of full power (-9 dB) 6/12 Arms
1/3 of full power (-5 dB) 14/28 Arms
At full power (0 dB) at 1 kHz 1% THD 16/32 Arms